Search results for "arterial occlusive disease"
showing 10 items of 39 documents
Comparison of contrast-enhanced MR angiography to intraarterial digital subtraction angiography for evaluation of peripheral arterial occlusive disea…
2010
Purpose To evaluate the efficacy and safety of 0.1 mmol/kg gadodiamide administration for contrast-enhanced magnetic resonance angiography (CE-MRA) in detecting hemodynamically relevant main stenosis (ie, ≥50% or occlusion) of aortoiliac arteries. Materials and Methods In a multicenter, phase 3, controlled study, patients with suspected or proven peripheral arterial occlusive disease (PAOD) underwent CE-MRA with administration of gadodiamide. Intraarterial digital subtraction angiography (IA-DSA) was used as the reference. The study was approved by all Institutional Review Boards or Institutional Ethic Committees prior to commencement of patient recruitment and written informed consent was …
Optical noninvasive monitoring of skin blood pulsations
2005
Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrh…
Antiplatelet effects of intravenous iloprost in patients with peripheral arterial obliterative disease
1986
The dose-dependent inhibition of platelet aggregation by the chemically stable, prostacyclin-mimetic, iloprost, was studied in patients suffering from stage II-III peripheral arterial obliterative disease (PAOD). The study was designed as a randomized placebo-controlled cross-over trial. Iloprost was administered i.v. to six patients at doses of 0.5, 1.0, 2.0 or 3.0 ng/kg X min for 4 h, with an interval of 2-3 days between the infusions. During iloprost infusion, systolic and diastolic arterial blood pressure, heart rate and blood flow in the affected limb remained unchanged. In contrast, there was a considerable, dose-dependent inhibition of ADP- and thrombin-induced platelet aggregation a…
Diagnostic performance of gadobenate dimeglumine enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicenter trial
2007
OBJECTIVE. The purpose of this study was to compare gadobenate dimeglumine–enhanced MR angiography and unenhanced time-of-flight MR angiography for the detection of significant peripheral arterial occlusive disease using digital subtraction angiography as our reference standard. SUBJECTS AND METHODS. Two hundred seventy-two patients underwent MR angiography and digital subtraction angiography of the iliofemoral arteries. MR angiography was performed before (2D time-of-flight acquisitions) and after (spoiled gradient-echo acquisitions) the administration of 0.1 mmol/kg of gadobenate dimeglumine at 1–2 mL/s. Contrast-enhanced MR angiography and digital subtraction angiography of the calf arte…
MR angiography of the pedal arteries with gadobenate dimeglumine, a contrast agent with increased relaxivity, and comparison with selective intraarte…
2007
Purpose To compare gadobenate dimeglumine (Gd-BOPTA)–enhanced MR angiography (i.e., contrast-enhanced MRA [CE-MRA]) of the pedal vasculature with selective digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). Materials and Methods A total of 22 patients with PAOD were prospectively examined at 1.5T. For contrast enhancement, 0.1 mmol/kg body weight of Gd-BOPTA were applied. MRA consisted of dynamic imaging with acquisition of six consecutive data sets. Acquisition time for each data set was 24 seconds, voxel size was 1.0 × 1.0 × 1.3 mm3. A total of 20 out of 22 patient underwent selective DSA, two patients fine-needle DSA. DSA and MRA were per…
One-year results from the DETOUR I trial of the PQ Bypass DETOUR System for percutaneous femoropopliteal bypass
2019
The objective of this study was to evaluate the 1-year safety and effectiveness outcomes associated with the PQ Bypass DETOUR System (PQ Bypass, Milpitas, Calif) for the percutaneous bypass of long-segment femoropopliteal occlusive disease.This prospective, single-arm, multicenter trial enrolled patients with long-segment femoropopliteal arterial disease. The DETOUR System percutaneously deploys modular stent grafts to bypass femoropopliteal lesions through a transvenous route. Eligible patients included those with TransAtlantic Inter-Society Consensus C and D lesions100 mm in length. The primary safety end point was the major adverse event (MAE) rate through 1 month, defined as the composi…
Short and long term results after intracoronary stenting in human coronary arteries: monocentre experience with the balloon-expandable Palmaz-Schatz …
1991
OBJECTIVE--Intracoronary stenting was designed to overcome acute complications after percutaneous transluminal coronary angioplasty and to achieve a reduced rate of restenosis, both of which are major limitations of this well accepted method for treating coronary heart disease. This report describes the experience at one centre with the implantation of balloon-expandable Palmaz-Schatz stents and focuses on device related complications and the short and long term angiographic outcome. DESIGN--A retrospective data analysis. PATIENTS--Stenting was attempted in 50 patients. Restenosis after an initially successful angioplasty procedure, inadequate postangioplasty results, saphenous coronary byp…
New balloon catheter for prolonged percutaneous transluminal coronary angioplasty and bypass flow in occluded vessels.
1986
A new balloon catheter was developed for continuous perfusion of coronary arteries during angioplasty (CPC catheter). Steerable Gruntzig balloon catheters (3.7 mm) with two lumina were formed. The first lumen was used for balloon inflation. Side holes to the second lumen proximally and distally to the balloon were created for coronary perfusion even during inflation phase. At a perfusion pressure of 120 mmHg, a flow rate of 63 +/- 3 ml/min with 0.9% saline and 43 +/- 1 ml/min with plasma expander were measured. In experiments on five dogs, dilation time until appearance of signs of ischemia could be prolonged in three of five dogs from 30 to 40 s, 120 to 203 s, and 180 to 420 s comparing co…
Bilateral photoplethysmography studies of the leg arterial stenosis.
2005
A newly developed portable multi-channel photoplethysmography (PPG) device has been used for comparative studies of 20 healthy control subjects and 45 patients with diagnosed arterial stenosis in a leg. The peripheral blood pulsations were detected simultaneously at four body sites-the same fingers and toes of both arms and legs. The PPG pulses recorded at the periphery of the stenotic leg, if compared with those of the healthy leg, were much weaker, with delayed arrival as a consequence of increased pulse wave transit time (PWTT) due to higher vascular resistance. The specific PWTT delays for the occluded legs were in the range of 20-80 ms, while in the case of healthy subjects the leg PPG…
Basilar Artery Occlusion and the Dense Artery Sign in the Newborn
1998
A child with basilar artery occlusion in the neonatal period is reported. The occlusion was documented by unenhanced computed tomography performed in the neonatal period demonstrating a “dense” artery at the tip of the basilar artery. The pattern of cerebral damage on MRI scan at 10 years of age confirmed the site of the vascular occlusion. The evidence suggests that embolization was the operating pathogenic mechanism of cerebral vascular occlusion. Neonatal arterial thrombosis involving the carotid circulation has been well documented and may be due to many pathological factors including direct trauma to the carotid artery and embolization from remote sites. Thrombosis of the vertebral art…